Eaton Cooper Power Series 38 kV Bay-O-Net Fuse Link for Pad-Mounted Transformer

Type: High Ampere Overload Bay-O-Net Fuse Link & Cartridge

Model Number: 4038361C03CB / 4038361C04CB / 4038361C05CB / 4038361C10CB

Rated Current: 65 A, 100 A, 125 A, and 200 A Solid Link (Delivers continuous current carrying capacity up to 185 A at 25°C ambient temperature)

Rated Voltage & Interruption: 8.3 kV Class (3500 A Symmetrical RMS Interrupting) / 15.5 kV Class (2500 A Symmetrical RMS Interrupting)

Application Layout: Explicitly engineered for overcurrent protection in large-capacity (high kVA) single-phase and three-phase pad-mounted distribution transformers. Provides advanced heat dissipation to significantly reduce operational temperatures under heavy loads.

System Coordination: Operates in flawless series synchronization with ELSP partial-range current-limiting backup fuses. Utilizes a highly robust integrated link-and-cartridge architecture to enable seamless, reliable field replacement via a standard hotstick.

Why Us?

  • Reliable Supply Chain
  • Quick Response
  • Technical Support
  • Genuine Product Authorization

Description

Product Specifications

Product Name: Eaton Cooper Power Series 38 kV Bay-O-Net Fuse Link

OEM Catalog Number: 4000380C06CB / 4000380C08CB / 4000380C10CB / 4000380C11CB / 4000380C12CB / 4000380C14CB

Maximum Rated System Voltage: 38.0 kV Class (Specifically rated for 24 kV to 38 kV high-voltage applications)

Fusing Curve Designation: Calibrated to standard full-size time-current characteristic curve parameters

Installation Mounting Profile: Sidewall-mounted or cover-mounted silver-plated Flapper valve assemblies

Core Materials: Integrated fuse link, heavy-duty fuse tube, and staked brass end plug


Available Amperage Series & Catalog Matrix

The Eaton Cooper Power series 38 kV high-voltage Bay-O-Net fuse link configuration is engineered across six distinct current ratings to meet comprehensive utility grid demand profiles:

  • 10 A Rating Variant: Part Number 4000380C06CB — Optimized for low-load 24–38 kV distribution networks.
  • 15 A Rating Variant: Part Number 4000380C08CB — Precision-drawn core engineered for mid-range transformer protection.
  • 25 A Rating Variant: Part Number 4000380C10CB — Heavy-duty variant calibrated for standard sub-surface apparatus layouts.
  • 30 A Rating Variant: Part Number 4000380C11CB — Extended performance core for specialized utility network installations.
  • 40 A Rating Variant: Part Number 4000380C12CB — Engineered structural profile built specifically for high-stress renewable energy networks.
  • 65 A Rating Variant: Part Number 4000380C14CB — Maximum capacity configuration delivering up to 1000 A single-phase interrupting capability.

Material & Structural Characteristics

  • Integrated Cartridge Assembly: Advanced design combining the fuse link and cartridge into a single component to simplify field re-fusing and completely prevent installation errors.
  • Silver-Plated Contact Interface: High-conductivity silver-plated flared contacts and end contacts engineered to achieve low electrical resistance and deliver absolute stability when inserted into silver-plated assemblies.
  • Rugged Fuse Tube Body: Heavy-duty, oil-compatible structural material designed to facilitate smooth dielectric fluid circulation and withstand aggressive thermal cycles without structural degradation.
  • Staked Brass End Plug: Factory-secured terminal hardware mechanically staked to completely prevent accidental removal or physical loosening under severe field conditions.

Product Functions

1. Overload & Low-Fault Clearing: Precision-calibrated to clear low-magnitude currents, secondary faults, line overloads, and high-impedance internal faults that fall below the operation threshold of upstream protective equipment.

2. Two-Fuse Coordinated Protection: Operates in perfect series synchronization when paired with a 38 kV rated ELSP current-limiting backup fuse, safely isolating minor overloads locally while leaving catastrophic short circuits to the backup component.

3. Apparatus Safety Isolation: Minimizes the duration of electrical arcing inside the transformer tank during an active insulation breakdown, preventing downstream fault escalation and protecting surrounding infrastructure.


Key Features

1. Renewable Energy Optimization: Specially engineered and certified to handle the rigorous overcurrent protection demands of modern solar, wind, and large-scale utility distribution applications.

2. Hotstick Operational Compatibility: Built to allow field technicians seamless removal and replacement using a standard hotstick from non-pressurized apparatus, eliminating the need for complex tools.

3. Dual Dielectric Compatibility: Formulated from premium non-aging materials that offer full operational compatibility with standard mineral oil and alternative bio-based Envirotemp FR3 fluids.

4. Permanent Part Stamping: Permanently marked with the exact factory catalog numbers and maximum voltage thresholds to ensure smooth inventory tracking and error-free warehouse deployment.

  • Single-Phase Interrupting Rating: Validated to deliver a 900 A interrupting capacity for 10 A through 40 A models, and a 1000 A capacity for the 65 A configuration when submerged in dielectric fluids.

  • Technical Parameter Specifications

    • Nominal System Voltage: 38.0 kV Maximum Single-Phase Rating
    • Interrupting Capacity (10A-40A): 900 A Symmetrical RMS in Mineral Oil and Envirotemp FR3 Fluid
    • Interrupting Capacity (65A): 1000 A Symmetrical RMS in Mineral Oil and Envirotemp FR3 Fluid
    • Interruption Medium: Liquid-Submersed Expulsion Link
    • Application Layout: Pad-Mounted Renewable Transformers, Wind Farm Substations, Solar Array Enclosures, Box-Type Sub-Surface Distribution Modules.
    • Compliance Matrix: Manufactured in complete alignment with IEEE Std C57.92 and IEEE Std C57.109 distribution component loading and through-fault specifications.

    FAQ

    Q1:How about your after-sales service?
    A:Our services are continuously. After an order is completed, we pay even closer attention to our customers. At every stage, our sales team will keep you updated on logistics information. If you have any questions after receiving the goods, including installation guidance, we will assist you promptly.
    A:Yes, we can
    A:It usually takes15- 30 days, but the exact timeframe depends on the product and order quantity. We will need to discuss with the manufacturing department.

    Accepted Delivery Terms: FOB, CIF, EXW, DDU;
    Accepted Payment Currency: USD;
    Accepted Payment Type: T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Western Union, Cash, Escrow;
    Language Spoken: English, Chinese

    Scroll to Top

    Leave Your Message

    Leave Your Message