Eaton Cooper Power Series 38 kV Bay-O-Net Fuse Link for Pad-Mounted Transformer

Type: High Ampere Overload Bay-O-Net Fuse Link & Cartridge

Model Number: 4038361C03CB / 4038361C04CB / 4038361C05CB / 4038361C10CB

Rated Current: 65 A, 100 A, 125 A, and 200 A Solid Link (Delivers continuous current carrying capacity up to 185 A at 25°C ambient temperature)

Rated Voltage & Interruption: 8.3 kV Class (3500 A Symmetrical RMS Interrupting) / 15.5 kV Class (2500 A Symmetrical RMS Interrupting)

Application Layout: Explicitly engineered for overcurrent protection in large-capacity (high kVA) single-phase and three-phase pad-mounted distribution transformers. Provides advanced heat dissipation to significantly reduce operational temperatures under heavy loads.

System Coordination: Operates in flawless series synchronization with ELSP partial-range current-limiting backup fuses. Utilizes a highly robust integrated link-and-cartridge architecture to enable seamless, reliable field replacement via a standard hotstick.

Why Us?

  • Reliable Supply Chain
  • Quick Response
  • Technical Support
  • Genuine Product Authorization

Description

Product Specifications

Product Name: Eaton Cooper Power Series 38 kV Bay-O-Net Fuse Link

OEM Catalog Number: 4000380C06CB / 4000380C08CB / 4000380C10CB / 4000380C11CB / 4000380C12CB / 4000380C14CB

Maximum Rated System Voltage: 38.0 kV Class (Specifically rated for 24 kV to 38 kV high-voltage applications)

Fusing Curve Designation: Calibrated to standard full-size time-current characteristic curve parameters

Installation Mounting Profile: Sidewall-mounted or cover-mounted silver-plated Flapper valve assemblies

Core Materials: Integrated fuse link, heavy-duty fuse tube, and staked brass end plug


Available Amperage Series & Catalog Matrix

The Eaton Cooper Power series 38 kV high-voltage Bay-O-Net fuse link configuration is engineered across six distinct current ratings to meet comprehensive utility grid demand profiles:

  • 10 A Rating Variant: Part Number 4000380C06CB — Optimized for low-load 24–38 kV distribution networks.
  • 15 A Rating Variant: Part Number 4000380C08CB — Precision-drawn core engineered for mid-range transformer protection.
  • 25 A Rating Variant: Part Number 4000380C10CB — Heavy-duty variant calibrated for standard sub-surface apparatus layouts.
  • 30 A Rating Variant: Part Number 4000380C11CB — Extended performance core for specialized utility network installations.
  • 40 A Rating Variant: Part Number 4000380C12CB — Engineered structural profile built specifically for high-stress renewable energy networks.
  • 65 A Rating Variant: Part Number 4000380C14CB — Maximum capacity configuration delivering up to 1000 A single-phase interrupting capability.

Material & Structural Characteristics

  • Integrated Cartridge Assembly: Advanced design combining the fuse link and cartridge into a single component to simplify field re-fusing and completely prevent installation errors.
  • Silver-Plated Contact Interface: High-conductivity silver-plated flared contacts and end contacts engineered to achieve low electrical resistance and deliver absolute stability when inserted into silver-plated assemblies.
  • Rugged Fuse Tube Body: Heavy-duty, oil-compatible structural material designed to facilitate smooth dielectric fluid circulation and withstand aggressive thermal cycles without structural degradation.
  • Staked Brass End Plug: Factory-secured terminal hardware mechanically staked to completely prevent accidental removal or physical loosening under severe field conditions.

Product Functions

1. Overload & Low-Fault Clearing: Precision-calibrated to clear low-magnitude currents, secondary faults, line overloads, and high-impedance internal faults that fall below the operation threshold of upstream protective equipment.

2. Two-Fuse Coordinated Protection: Operates in perfect series synchronization when paired with a 38 kV rated ELSP current-limiting backup fuse, safely isolating minor overloads locally while leaving catastrophic short circuits to the backup component.

3. Apparatus Safety Isolation: Minimizes the duration of electrical arcing inside the transformer tank during an active insulation breakdown, preventing downstream fault escalation and protecting surrounding infrastructure.


Key Features

1. Renewable Energy Optimization: Specially engineered and certified to handle the rigorous overcurrent protection demands of modern solar, wind, and large-scale utility distribution applications.

2. Hotstick Operational Compatibility: Built to allow field technicians seamless removal and replacement using a standard hotstick from non-pressurized apparatus, eliminating the need for complex tools.

3. Dual Dielectric Compatibility: Formulated from premium non-aging materials that offer full operational compatibility with standard mineral oil and alternative bio-based Envirotemp FR3 fluids.

4. Permanent Part Stamping: Permanently marked with the exact factory catalog numbers and maximum voltage thresholds to ensure smooth inventory tracking and error-free warehouse deployment.

  • Single-Phase Interrupting Rating: Validated to deliver a 900 A interrupting capacity for 10 A through 40 A models, and a 1000 A capacity for the 65 A configuration when submerged in dielectric fluids.

  • Technical Parameter Specifications

    • Nominal System Voltage: 38.0 kV Maximum Single-Phase Rating
    • Interrupting Capacity (10A-40A): 900 A Symmetrical RMS in Mineral Oil and Envirotemp FR3 Fluid
    • Interrupting Capacity (65A): 1000 A Symmetrical RMS in Mineral Oil and Envirotemp FR3 Fluid
    • Interruption Medium: Liquid-Submersed Expulsion Link
    • Application Layout: Pad-Mounted Renewable Transformers, Wind Farm Substations, Solar Array Enclosures, Box-Type Sub-Surface Distribution Modules.
    • Compliance Matrix: Manufactured in complete alignment with IEEE Std C57.92 and IEEE Std C57.109 distribution component loading and through-fault specifications.

    FAQ

    Q1: Are your ABB and Eaton Cooper components genuine?

    A: Yes, absolutely. Nanjing Hyston Electric is an authorized distributor for both ABB and Eaton Cooper transformer components. We guarantee that 100% of our branded products are genuine and factory-certified. For maximum safety and compliance under high-voltage conditions, our product lines hold global certifications from KEMA, DEKRA, and ABS.

    A: In the power industry, the delivery time of a complete transformer actually depends on the lead time of its individual components. To help you eliminate assembly bottlenecks, we manage our logistics into two tiers:
      • In-Stock Items: Core components like bushings and bushing wells are maintained in our safety stock and are available for immediate shipment.
      • Non-Stock Items: Backed by Cooper’s high-volume manufacturing lines, we guarantee a stable, worry-free supply chain to keep your final transformer production strictly on schedule.

    A: Yes. We offer a one-stop procurement solution to simplify your sourcing. Our catalog includes:
      • Medium-to-High Voltage Cable Accessories: T-bodies, elbows, straight connectors, and surge arresters.
      • Essential Transformer Materials: Insulation boards (DDP/DMD/YMY), magnet wires, and fabricated tanks.

    A: Supported by automated production lines and a robust supply chain, our combined monthly output across core categories exceeds 50,000 units. We consistently maintain a 20% to 30% capacity reserve to fast-track urgent grid upgrades or large-scale industrial projects.
    A: We maintain high-volume, reliable monthly supply capacities to minimize lead times for our clients:
      • Bay-O-Net Assemblies & Links: 12,000+ sets/month
      • ELSP Backup Fuses: 8,000+ pcs/month
      • High-Voltage Bushings: 6,000+ pcs/month
      • Tap Changers : 2,000+ pcs/month
      • Load Break Switches: Up to 1,000 units/month

    A: Our top-tier manufacturing lines deliver high-volume outputs optimized for power distribution networks:
      • Dropout Fuses: 24,000+ units/month (for immediate large-scale delivery)
      • Cold-Shrink Tubing: 3,000+ sets/month
      • Cable Accessories (Elbows/T-Connectors): 1,000+ sets/month
      • Surge Arresters (TVP Optimized): 1,000+ pcs/month
      • Extra-High Voltage (EHV) Terminations: 200+ sets/month

    Scroll to Top