Eaton Cooper Power Series 38kV 200kV-BIL Bay-O-Net Fuse Assembly with Flapper Valve 4038380B03M for Solar & Wind Box-Transformer

Max. Voltage: 38kV (200 kV BIL)

Interrupting Rating: 900A symmetrical (10-40A) / 1,000A symmetrical (65A)

Model Number: 4038380B03M (Compatible with 38kV fuse links)

Key Materials: High-Temperature Thermo-Plastic, Silver-Plated Copper Contacts, Standard Flapper Valve, Nitrile Gaskets.

Application: Under-oil sidewall-mounted fuse holder assembly for 38kV solar/wind transformers and utilities. Features standard silver-plated contacts and integrated flapper oil-spill valve. Coordinates with ELSP backup fuses.

Why Us?

  • Reliable Supply Chain
  • Quick Response
  • Technical Support
  • Genuine Product Authorization

Description

Product Specifications

Product Name: Eaton Cooper Power Series 38kV Sidewall-Mounted Bay-O-Net Fuse Assembly

Rated Voltage: 38kV Class (200 kV BIL Full Wave Crest)

Rated Current: Suitable for 38kV Bay-O-Net Integral Cartridge Links (10A to 65A)

Type: 38kV Under-Oil Plug-in Fuse Tube Assembly (With Standard Flapper Valve)

Color: Black


Standard Models & Components

  • 38 kV Silver-Plated Assembly with Inner Holder: 4038380B03M
  • Replacement Inner Holder Only: 4000715B02M
  • Replacement Outer Tube Only: 4037158C11M (Silver-plated, with contacts, gasket, and nut)

Material & Structural Characteristics

  • Outer Tube Assembly: Molded high-temperature engineered thermo-plastic tube designed to withstand severe electrical stress.
  • Terminals & Contacts: One-piece high-conductivity silver-plated copper terminals (Standard requirement for 38kV configurations).
  • Contact Buttons: Independent silver-plated spring copper buttons featuring an anti-annealing design.
  • Valve System: Standard integrated silver-plated Flapper™ valve mechanism to seal oil upon removal.
  • Sealing Gaskets: High-performance multiple groove Nitrile rubber tank wall gasket ensuring a tight compression seal.

Product Functions

1. Specialized 38kV System Protection: Engineered exclusively for 38kV class pad-mounted or subsurface distribution transformers, providing premium deadfront safety and convenient hotstick operation.

2. Mandatory High-Current Coordination: Designed strictly for series coordination with a 38kV partial-range current-limiting backup fuse (such as ELSP) to safely isolate high-current internal transformer faults.

3. Automated Oil Environmental Control: Equipped with a standard heavy-duty Flapper™ valve that instantly snaps shut when the inner fuse cartridge holder is withdrawn, effectively preventing oil spillage, pad tilting sensitivity, and moisture ingress.


Key Features

1. 200 kV BIL Heavy-Duty Insulation: Delivers outstanding electrical dielectric strength, fully tested to withstand a 200 kV BIL lightning impulse and a 70 kV power frequency AC 1-minute test, far exceeding standard 23kV parameters.

2. Standard Silver-Plated Power Path: Features premium silver-plated terminals and contact buttons as standard to ensure maximum current-carrying capability, minimal temperature rise, and exceptional annealing resistance under heavy load.

3. Dual Gas Expulsion Ports: Features precision-molded internal gas ports within the thermo-plastic outer tube to rapidly direct and release arc gases during fuse operation, successfully preventing over-pressure and restrike.

4. Ergonomic Cam-Action Sealing: The stick-operable handle features a robust mechanical cam action that ensures a complete hermetic fluid seal when locked, and effortless insertion/removal during live field operation.

5. Reliable Tank状况 Sealing: Designed with a 7-degree tapered flange that properly compresses and retains the nitrile rubber seal against the tank wall, ensuring a 100% leak-proof installation.


Technical Parameter Specifications

  • Max. Voltage: 38kV (200 kV BIL Full Wave)
  • Interrupting Rating: 900A symmetrical for 10-40A links / 1,000A symmetrical for 65A links
  • Model Number: 4038380B03M (Compatible with CA132006EN 38kV Fuse Links)
  • Primary Applications: Renewable Energy (Solar/Wind) Box Transformers, Power Utilities, Industrial Substation Switchgear.
  • Key Materials: High-Temperature Thermo-Plastic, Silver-Plated Copper Contacts, Nitrile Gaskets. Fully complies with standard IEEE and IEC electrical manufacturing specifications.

FAQ

Q1: Are your ABB and Eaton Cooper components genuine?

A: Yes, absolutely. Nanjing Hyston Electric is an authorized distributor for both ABB and Eaton Cooper transformer components. We guarantee that 100% of our branded products are genuine and factory-certified. For maximum safety and compliance under high-voltage conditions, our product lines hold global certifications from KEMA, DEKRA, and ABS.

A: In the power industry, the delivery time of a complete transformer actually depends on the lead time of its individual components. To help you eliminate assembly bottlenecks, we manage our logistics into two tiers:
    • In-Stock Items: Core components like bushings and bushing wells are maintained in our safety stock and are available for immediate shipment.
    • Non-Stock Items: Backed by Cooper’s high-volume manufacturing lines, we guarantee a stable, worry-free supply chain to keep your final transformer production strictly on schedule.

A: Yes. We offer a one-stop procurement solution to simplify your sourcing. Our catalog includes:
    • Medium-to-High Voltage Cable Accessories: T-bodies, elbows, straight connectors, and surge arresters.
    • Essential Transformer Materials: Insulation boards (DDP/DMD/YMY), magnet wires, and fabricated tanks.

A: Supported by automated production lines and a robust supply chain, our combined monthly output across core categories exceeds 50,000 units. We consistently maintain a 20% to 30% capacity reserve to fast-track urgent grid upgrades or large-scale industrial projects.
A: We maintain high-volume, reliable monthly supply capacities to minimize lead times for our clients:
    • Bay-O-Net Assemblies & Links: 12,000+ sets/month
    • ELSP Backup Fuses: 8,000+ pcs/month
    • High-Voltage Bushings: 6,000+ pcs/month
    • Tap Changers : 2,000+ pcs/month
    • Load Break Switches: Up to 1,000 units/month

A: Our top-tier manufacturing lines deliver high-volume outputs optimized for power distribution networks:
    • Dropout Fuses: 24,000+ units/month (for immediate large-scale delivery)
    • Cold-Shrink Tubing: 3,000+ sets/month
    • Cable Accessories (Elbows/T-Connectors): 1,000+ sets/month
    • Surge Arresters (TVP Optimized): 1,000+ pcs/month
    • Extra-High Voltage (EHV) Terminations: 200+ sets/month

Scroll to Top

Leave Your Message

Leave Your Message