Eaton Cooper Power Series 200A 15kV Class Loadbreak Elbow Connector LE215 / LEJ215 for Underground Cable Connection
Current Rating: 200A rms Continuous / 10,000A rms Symmetrical Short Time
Voltage Rating: 15kV Class (95 kV BIL Full Wave Crest)
Model Series: LE215 (Standard) / LEJ215 (With Optional Integral Jacket Seal)
Key Specs: Molded peroxide-cured EPDM rubber, tin-plated copper probe with ablative arc-follower tip, stainless steel reinforced pulling eye, complies with IEEE Std 386™-2006.
Application: Fully-shielded, insulated deadfront plug-in termination connecting underground cables to pad-mounted transformers, switchgear, and cable junctions.
Why Us?
- Reliable Supply Chain
- Quick Response
- Technical Support
- Genuine Product Authorization
Description
Product Specifications
Product Name: Eaton Cooper Power Series 200A 15kV Class Loadbreak Elbow ConnectorRated Voltage: 15kV Class (Maximum 14.4kV Phase-to-Phase / 8.3kV Phase-to-Ground)Rated Current: 200A rms Continuous / 200A rms Switching (10 operations at 14.4 kV)Type: Fully-Shielded and Insulated Plug-in Loadbreak TerminationColor: BlackAvailable Models & Series Selection
- Standard Elbow with Capacitive Test Point: LE215 [Cable Code] [Conductor Code] T
- Standard Elbow without Capacitive Test Point: LE215 [Cable Code] [Conductor Code]
- Integral Jacket Seal Elbow with Test Point: LEJ215 [Cable Code] [Conductor Code] T
- Integral Jacket Seal Elbow without Test Point: LEJ215 [Cable Code] [Conductor Code]
- Common Replacement Components: Hold down bail assembly (2638351C01B), Loadbreak band package (2639139B01B), Probe Kit (PK215).
Material & Construction Detail
- Insulation & Shield Body: In-house formulated, high-quality peroxide-cured EPDM rubber ensuring reliable deadfront safety.
- Loadbreak Probe: High-conductivity tin-plated copper probe equipped with an advanced ablative arc-follower tip.
- Pulling Eye: Heavy-duty stainless steel reinforced pulling eye designed for positive hotstick switching operations.
- Compression Connector: Premium coppertop connector featuring an inertia-welded aluminum barrel and threaded copper lug.
- Loadbreak Band: UV-resistant field-replaceable nylon band identifying three-phase loadbreak rating.
Product Functions
1. Insulated Underground Termination: Provides a fully-shielded, submersible, and insulated plug-in connection to seamlessly terminate underground high-voltage cables to pad-mounted transformers, switching cabinets, and junctions.2. 200A Loadbreak Switching: Acts as a fully rated 200 A loadbreak switching device operable with a hotstick under live-line conditions, simplifying engineering operation and routine maintenance.3. Enhanced Moisture Ingress Sealing: The optional integral jacket seal (LEJ215 series) is molded directly to the elbow body, providing a quick, robust seal to the cable jacket to prevent moisture ingress without separate sealing products.Key Features
1. Peroxide-Cured EPDM Integrity: Molded using high-quality peroxide-cured insulating and semi-conducting EPDM rubber, delivering uniform electrical stress distribution and excellent resistance to thermocycling or interface tracking.2. Dependable Arc-Ablative Technology: The tin-plated copper probe incorporates an advanced ablative arc follower tip to guarantee crisp, highly reliable arc-extinguishing and dependable loadbreak switching characteristics.3. Convenient Capacitive Test Point: Equipped with an optional corrosion-resistant, conductive plastic test point electrode, providing a consistent capacitive voltage source for fault indicator application and easy hotstick circuit-energized checking.4. Inertia-Welded Coppertop Connector: Features a high-reliability transition connector where the aluminum barrel is inertia-welded to a copper lug, ensuring low-resistance, tight, cool electrical operation with the probe.5. Reliable Deadfront Safety Protection: Formulated with molded-in grounding tabs attached to the semi-conductive shield, ensuring a continuous solid path to ground and fulfilling all protective requirements of standard electrical specifications.Technical Parameter Specifications
- Impulse Withstand (BIL): 95 kV Full Wave Crest
- AC 60 Hz 1 Minute Withstand: 34 kV
- Minimum Corona Voltage Level: 11 kV
- Fault Closure Rating: 10,000A rms symmetrical at 14.4 kV for 0.17 s (After 10 switching operations)
- Short Time Rating: 10,000A rms symmetrical for 0.17 s / 3,500A rms symmetrical for 3.0 s
- Standard Compliance: Designed and fully tested in accordance with IEEE Std 386™ and IEEE Std 592™ manufacturing guidelines.
- Primary Applications: Underground Residential Distribution (URD) Loop-Feed Systems, Pad-mounted Transformer Vaults, Distribution Switching Cabinets, Cable Junction Boxes.
- Core Engineering Materials: Peroxide-Cured EPDM Rubber, Tin-Plated Copper Probe, Inertia-Welded Aluminum/Copper Lug, Mastic Sealing.
FAQ
Q1:How about your after-sales service?
Q2:We only need some products inner parts/components, could you sell that?
Q3:How long is our delivery time?
Q4. what services can we provide?
Accepted Delivery Terms: FOB, CIF, EXW, DDU;
Accepted Payment Currency: USD;
Accepted Payment Type: T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Western Union, Cash, Escrow;
Language Spoken: English, Chinese
Related products
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series 8.3kV 50kA-Interrupting ELSP Under-Oil Backup Current-Limiting Fuse for Pad-Mounted Transformer
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series 300A Externally Operated Non-Excited Tap-Changer Switch 2237179C02M for Substation Transformer