Eaton Cooper Power Series 15.2 kV 600 A Symmetrical Type Screened Deadbreak T-Body Cable Connector

Type: IEC Shielded Deadbreak Symmetrical Bolted T-Body Cable Connector

OEM Framework Designation: DT400 / DT436 Symmetrical Array Configuration Series

Voltage & Current Thresholds: Precision-rated for 15.2 kV / 24 kV Maximum System Voltage (Um) with a 600 A to 630 A continuous current capacity (Engineered to withstand up to 900 A heavy overload operations lasting up to 8 hours).

Mating Interface Compatibility: Standardized European DIN 47636 and CENELEC EN 50180 / EN 50181 Interface C Sub-Surface Connection Profiles.

Core Application Layout: Explicitly engineered to deliver balanced, deadfront high-voltage terminal links inside medium-voltage gas-insulated switchgear (GIS) cabinets, outdoor pad-mounted step-up distribution transformers, and underground cable branching boxes. Supplied complete with a factory-tested tin-plated copper clamping double-headed bolt assembly.

Why Us?

  • Reliable Supply Chain
  • Quick Response
  • Technical Support
  • Genuine Product Authorization

Description

Product Specifications

Product Name/Series: Eaton Cooper Power Series Shielded Symmetrical T-Body Cable Connector (DT400/DT436 Series)

Maximum Rated System Voltage (Um): 24 kV Class (Perfectly optimized for standard 12/20 kV, 15 kV, and 15.2 kV distribution grids)

  • Lightning Impulse Insulation Withstand: 125 kV Peak Crest Parameters.
  • AC Power Frequency 5-Minute Withstand Voltage: 54 kV rms Symmetrical Baseline.

Continuous Base Current Capacity: Rated for 600 A / 630 A continuous current carrying loops with an 8-hour maximum overload capacity of 900 A.

Short Circuit Fault Current Withstand: Validated up to 35 kA Symmetrical Peak for 1 full second duration.

Cable Cross-Section Accommodations: Accommodates extruded polymeric cables (XLPE/EPR) ranging seamlessly from 35 mm² up to 400 mm².


Symmetrical Array & Voltage Configuration Matrix

The Eaton Cooper Power series symmetrical deadbreak T-connector infrastructure is tightly structured across dedicated catalog codes to handle distinct insulation outer diameters and core dimensions:

  • Low-Range Conductor Layouts (35 mm² – 70 mm²): Utilizing specialized inner stress relief cones tailored for tight core clearances in utility branching circuits.
  • Mid-Range Distribution Layouts (95 mm² – 240 mm²): Precision-calibrated to fit standard domestic and import single-phase or three-phase underground industrial networks.
  • High-Stress的大截面 Layouts (300 mm² – 400 mm²): Utilizing rugged heavy-gauge bimetallic inertia-welded compression connectors built for wind array clusters and solar farm step-up loops.

Material & Structural Characteristics

  • Direct-Molded Peroxide-Cured EPDM Rubber: Formulated, mixed, and molded entirely in-house to create a uniform, high-density insulation body that resists chemical oxidation and polymer tracking in severe environments.
  • Semi-Conductive External EPDM Shielding Screen: Heavy-duty, molded outer skin that remains at absolute zero earth potential during live grid operation, ensuring 100% deadfront safe operator exposure.
  • Pre-Molded Internal Geometric Stress Relief Cone: Advanced stress cone profile formulated to systematically smooth out high-voltage electrical field concentrations around the cable screen break.
  • Tin-Plated High-Torque Double-Headed Clamping Screw: Heavy-gauge brass clamping hardware ensures low contact resistance and eliminates thermal drift under constant transformer vibration.
  • Molded-In Screen Earthing Eyes: Features integrated, low-impedance grounding loop links pre-molded into the outer jacket to allow fast connection of copper earth drain lines.
  • Dual Capacitive Test Points with EPDM Protective Caps: Equipped with an internal capacitive test point under a watertight grounding shield cap to allow safe circuit voltage status checking via standard line indicators.

Product Functions

1. Symmetric High-Voltage Potential Balancing: The symmetrical T-body design distributes physical installation stress evenly across switchgear bushings, minimizing mechanical bending moments in compact cabinets.

2. Deadfront Hermetic Submersion Shielding: Establishes a 100% fully screened, fully submersible, and dust-tight cable connection link that operates safely even under long-term direct water submersion.

3. Sectionalizing Grid Isolation Flexibility: Serves as a versatile disconnect terminal block; its rear-facing C-interface can be safely sealed with an epoxy insulating plug or expanded with rear coupling surge arresters.


Key Features

1. Zero Safe Phase Air Gap Requirement: Fully insulated deadfront geometry removes the need for standard phase-to-phase air separation clearances, dramatically down-scaling the total footprint of switchgear enclosures.

2. Tool-Free Quick Field Deployment: Requires no specialized hydraulic field-heating or chemical wrapping tapes; the entire component block is ready for full-load energization immediately after securing the tightening stud.

3. Non-Aging Bio-Fluid Chemical Compatibility: Formulated using premium polymers proven to maintain total structural stability and zero swelling when fully submersed in hot transformer mineral oil or plant-based Envirotemp FR3 fluids.

4. 100% Factory Partial Discharge Certification: Every production unit undergoes definitive automation quality tests including high-pC micro-volt screening, 100% partial discharge testing under 10 pC thresholds, and periodic X-ray integrity analysis.

FAQ

Q1: Are your ABB and Eaton Cooper components genuine?

A: Yes, absolutely. Nanjing Hyston Electric is an authorized distributor for both ABB and Eaton Cooper transformer components. We guarantee that 100% of our branded products are genuine and factory-certified. For maximum safety and compliance under high-voltage conditions, our product lines hold global certifications from KEMA, DEKRA, and ABS.

A: In the power industry, the delivery time of a complete transformer actually depends on the lead time of its individual components. To help you eliminate assembly bottlenecks, we manage our logistics into two tiers:
    • In-Stock Items: Core components like bushings and bushing wells are maintained in our safety stock and are available for immediate shipment.
    • Non-Stock Items: Backed by Cooper’s high-volume manufacturing lines, we guarantee a stable, worry-free supply chain to keep your final transformer production strictly on schedule.

A: Yes. We offer a one-stop procurement solution to simplify your sourcing. Our catalog includes:
    • Medium-to-High Voltage Cable Accessories: T-bodies, elbows, straight connectors, and surge arresters.
    • Essential Transformer Materials: Insulation boards (DDP/DMD/YMY), magnet wires, and fabricated tanks.

A: Supported by automated production lines and a robust supply chain, our combined monthly output across core categories exceeds 50,000 units. We consistently maintain a 20% to 30% capacity reserve to fast-track urgent grid upgrades or large-scale industrial projects.
A: We maintain high-volume, reliable monthly supply capacities to minimize lead times for our clients:
    • Bay-O-Net Assemblies & Links: 12,000+ sets/month
    • ELSP Backup Fuses: 8,000+ pcs/month
    • High-Voltage Bushings: 6,000+ pcs/month
    • Tap Changers : 2,000+ pcs/month
    • Load Break Switches: Up to 1,000 units/month

A: Our top-tier manufacturing lines deliver high-volume outputs optimized for power distribution networks:
    • Dropout Fuses: 24,000+ units/month (for immediate large-scale delivery)
    • Cold-Shrink Tubing: 3,000+ sets/month
    • Cable Accessories (Elbows/T-Connectors): 1,000+ sets/month
    • Surge Arresters (TVP Optimized): 1,000+ pcs/month
    • Extra-High Voltage (EHV) Terminations: 200+ sets/month

Scroll to Top

Leave Your Message

Leave Your Message