Eaton Cooper Power Series 300A Externally Operated Non-Excited Tap-Changer Switch 2237179C02M for Substation Transformer

Max. Current: 300A

Max. Voltage: 35kV (150kV BIL)

Model Numbers: 2237500C36 / 223471C16M / 2237179C02M

Key Materials: Silver-Plated Copper Contacts, Glass-Reinforced Nylon Shaft, Premium Viton O-Rings.

Application: Externally operated non-excited (off-circuit) tap switch for single/three-phase distribution transformers. Features high-speed snap action and double O-ring leak-proof sealing.

Why Us?

  • Reliable Supply Chain
  • Quick Response
  • Technical Support
  • Genuine Product Authorization

Description

Product Specifications

Product Name: Oil-Immersed 300A Externally Operated Tap-Changer Switch

Rated Voltage: 35kV Max Voltage Class (150kV BIL)

Rated Current: 300A rms Continuous

Type: Externally Operated Non-Excited (Off-Circuit) Tap-Changer Switch

Color: Black Body with Bright Brass End Caps


Standard Models & Phase Configurations

  • Single-Phase (1-Deck): 2237500C36 (Equipped with 1/4-20 bolts hardware)
  • Two-Phase (2-Decks): 223471C16M (Side-mounted configuration)
  • Three-Phase (3-Decks): 2237179C02M (Complete 3-phase synchronized assembly)

Material & Structural Characteristics

  • Switch Body: Premium high-performance glass-filled polyester delivering superior dielectric insulation strength.
  • Operating Shaft: High-strength, non-conductive glass-reinforced nylon shaft.
  • Contacts & Terminals: Heavy-duty silver-plated copper contacts ensuring zero localized overheating.
  • Sealing System: Dual high-temperature Viton/Fluorocarbon O-rings guaranteeing complete fluid-tight integrity.

Product Functions

1. Safe External Voltage Regulation: Allows the transformer’s primary coil voltage ratio to be safely adjusted from outside the tank, completely eliminating the need to open the tank cover or expose operators to internal components.

2. Fluid Contamination Prevention: Fully under-oil design prevents carbon tracking, external arcing, and dielectric contamination inside the main transformer tank during scheduled voltage adjustment.

3. Universal Distribution Adaptation: Perfectly adapts to various single-phase and three-phase distribution transformers to achieve precise, multi-position voltage shifting.


Key Features

1. High-Speed Snap Action: Engineered with a robust over-center snap-action mechanism to ensure positive contact engagement and quick, crisp position transitioning independent of handle turning speed.

2. Dead-Front Safety Design: Strictly configured for de-energized voltage regulation, completely avoiding the risk of load-break arcing and flashovers, ensuring high mechanical and electrical security.

3. Superior Environmental Sealing: Equipped with a double O-ring shaft sealing system to ensure total fluid-tight integrity and prevent oil leakage or moisture ingress in harsh outdoor environments.

4. Flexible Phase Configurations: Available in 1, 2, or 3-deck options to flexibly accommodate diverse transformer internal wiring designs and physical spacing requirements.

5. Reliable Position Locking: Features a rugged external index plate with clear markings and a pad-lockable handle option to strictly prevent unauthorized or accidental operation.


Technical Parameter Specifications

  • Max. Current: 300A rms Continuous
  • Max. Voltage: 35kV (BIL withstand up to 150 kV)
  • Model Numbers: 2237500C36 / 223471C16M / 2237179C02M
  • Primary Applications: Electric Power Industry, Pad-mounted Distribution Transformers, Substation Equipment, Off-Circuit Voltage Adjustment.
  • Standard Compliance: Manufactured and tested to fully meet rigorous IEEE and IEC standard manufacturing specifications.

FAQ

Q1: Are your ABB and Eaton Cooper components genuine?

A: Yes, absolutely. Nanjing Hyston Electric is an authorized distributor for both ABB and Eaton Cooper transformer components. We guarantee that 100% of our branded products are genuine and factory-certified. For maximum safety and compliance under high-voltage conditions, our product lines hold global certifications from KEMA, DEKRA, and ABS.

A: In the power industry, the delivery time of a complete transformer actually depends on the lead time of its individual components. To help you eliminate assembly bottlenecks, we manage our logistics into two tiers:
    • In-Stock Items: Core components like bushings and bushing wells are maintained in our safety stock and are available for immediate shipment.
    • Non-Stock Items: Backed by Cooper’s high-volume manufacturing lines, we guarantee a stable, worry-free supply chain to keep your final transformer production strictly on schedule.

A: Yes. We offer a one-stop procurement solution to simplify your sourcing. Our catalog includes:
    • Medium-to-High Voltage Cable Accessories: T-bodies, elbows, straight connectors, and surge arresters.
    • Essential Transformer Materials: Insulation boards (DDP/DMD/YMY), magnet wires, and fabricated tanks.

A: Supported by automated production lines and a robust supply chain, our combined monthly output across core categories exceeds 50,000 units. We consistently maintain a 20% to 30% capacity reserve to fast-track urgent grid upgrades or large-scale industrial projects.
A: We maintain high-volume, reliable monthly supply capacities to minimize lead times for our clients:
    • Bay-O-Net Assemblies & Links: 12,000+ sets/month
    • ELSP Backup Fuses: 8,000+ pcs/month
    • High-Voltage Bushings: 6,000+ pcs/month
    • Tap Changers : 2,000+ pcs/month
    • Load Break Switches: Up to 1,000 units/month

A: Our top-tier manufacturing lines deliver high-volume outputs optimized for power distribution networks:
    • Dropout Fuses: 24,000+ units/month (for immediate large-scale delivery)
    • Cold-Shrink Tubing: 3,000+ sets/month
    • Cable Accessories (Elbows/T-Connectors): 1,000+ sets/month
    • Surge Arresters (TVP Optimized): 1,000+ pcs/month
    • Extra-High Voltage (EHV) Terminations: 200+ sets/month

Scroll to Top