Eaton Cooper Power Series 300A Externally Operated Non-Excited Tap-Changer Switch 2237179C02M for Substation Transformer
Max. Current: 300A
Max. Voltage: 35kV (150kV BIL)
Model Numbers: 2237500C36 / 223471C16M / 2237179C02M
Key Materials: Silver-Plated Copper Contacts, Glass-Reinforced Nylon Shaft, Premium Viton O-Rings.
Application: Externally operated non-excited (off-circuit) tap switch for single/three-phase distribution transformers. Features high-speed snap action and double O-ring leak-proof sealing.
Why Us?
- Reliable Supply Chain
- Quick Response
- Technical Support
- Genuine Product Authorization
Description
Product Specifications
Product Name: Oil-Immersed 300A Externally Operated Tap-Changer Switch
Rated Voltage: 35kV Max Voltage Class (150kV BIL)
Rated Current: 300A rms Continuous
Type: Externally Operated Non-Excited (Off-Circuit) Tap-Changer Switch
Color: Black Body with Bright Brass End Caps
Standard Models & Phase Configurations
- Single-Phase (1-Deck): 2237500C36 (Equipped with 1/4-20 bolts hardware)
- Two-Phase (2-Decks): 223471C16M (Side-mounted configuration)
- Three-Phase (3-Decks): 2237179C02M (Complete 3-phase synchronized assembly)
Material & Structural Characteristics
- Switch Body: Premium high-performance glass-filled polyester delivering superior dielectric insulation strength.
- Operating Shaft: High-strength, non-conductive glass-reinforced nylon shaft.
- Contacts & Terminals: Heavy-duty silver-plated copper contacts ensuring zero localized overheating.
- Sealing System: Dual high-temperature Viton/Fluorocarbon O-rings guaranteeing complete fluid-tight integrity.
Product Functions
1. Safe External Voltage Regulation: Allows the transformer’s primary coil voltage ratio to be safely adjusted from outside the tank, completely eliminating the need to open the tank cover or expose operators to internal components.
2. Fluid Contamination Prevention: Fully under-oil design prevents carbon tracking, external arcing, and dielectric contamination inside the main transformer tank during scheduled voltage adjustment.
3. Universal Distribution Adaptation: Perfectly adapts to various single-phase and three-phase distribution transformers to achieve precise, multi-position voltage shifting.
Key Features
1. High-Speed Snap Action: Engineered with a robust over-center snap-action mechanism to ensure positive contact engagement and quick, crisp position transitioning independent of handle turning speed.
2. Dead-Front Safety Design: Strictly configured for de-energized voltage regulation, completely avoiding the risk of load-break arcing and flashovers, ensuring high mechanical and electrical security.
3. Superior Environmental Sealing: Equipped with a double O-ring shaft sealing system to ensure total fluid-tight integrity and prevent oil leakage or moisture ingress in harsh outdoor environments.
4. Flexible Phase Configurations: Available in 1, 2, or 3-deck options to flexibly accommodate diverse transformer internal wiring designs and physical spacing requirements.
5. Reliable Position Locking: Features a rugged external index plate with clear markings and a pad-lockable handle option to strictly prevent unauthorized or accidental operation.
Technical Parameter Specifications
- Max. Current: 300A rms Continuous
- Max. Voltage: 35kV (BIL withstand up to 150 kV)
- Model Numbers: 2237500C36 / 223471C16M / 2237179C02M
- Primary Applications: Electric Power Industry, Pad-mounted Distribution Transformers, Substation Equipment, Off-Circuit Voltage Adjustment.
- Standard Compliance: Manufactured and tested to fully meet rigorous IEEE and IEC standard manufacturing specifications.
FAQ
Q1: Are your ABB and Eaton Cooper components genuine?
A: Yes, absolutely. Nanjing Hyston Electric is an authorized distributor for both ABB and Eaton Cooper transformer components. We guarantee that 100% of our branded products are genuine and factory-certified. For maximum safety and compliance under high-voltage conditions, our product lines hold global certifications from KEMA, DEKRA, and ABS.
Q2: What is your standard lead time for transformer accessories?
- In-Stock Items: Core components like bushings and bushing wells are maintained in our safety stock and are available for immediate shipment.
- Non-Stock Items: Backed by Cooper’s high-volume manufacturing lines, we guarantee a stable, worry-free supply chain to keep your final transformer production strictly on schedule.
Q3: Do you supply raw transformer materials and cable accessories?
- Medium-to-High Voltage Cable Accessories: T-bodies, elbows, straight connectors, and surge arresters.
- Essential Transformer Materials: Insulation boards (DDP/DMD/YMY), magnet wires, and fabricated tanks.
Q4: What is your monthly production capacity for power components?
Q5: What is your supply capacity for pad-mounted transformer components?
- Bay-O-Net Assemblies & Links: 12,000+ sets/month
- ELSP Backup Fuses: 8,000+ pcs/month
- High-Voltage Bushings: 6,000+ pcs/month
- Tap Changers : 2,000+ pcs/month
- Load Break Switches: Up to 1,000 units/month
Q6: What is your production capacity for cable accessories and protection products?
- Dropout Fuses: 24,000+ units/month (for immediate large-scale delivery)
- Cold-Shrink Tubing: 3,000+ sets/month
- Cable Accessories (Elbows/T-Connectors): 1,000+ sets/month
- Surge Arresters (TVP Optimized): 1,000+ pcs/month
- Extra-High Voltage (EHV) Terminations: 200+ sets/month
Related products
- Pad-Mounted Transformer Accessories
ABB 345B995G31 Oil-Immersed Expulsion Protective Mesh Link for 34.5 kV Class Distribution Transformer