Eaton Cooper Power Series 15.2 kV 600 A Symmetrical Type Screened Deadbreak T-Body Cable Connector
Type: IEC Shielded Deadbreak Symmetrical Bolted T-Body Cable Connector
OEM Framework Designation: DT400 / DT436 Symmetrical Array Configuration Series
Voltage & Current Thresholds: Precision-rated for 15.2 kV / 24 kV Maximum System Voltage (Um) with a 600 A to 630 A continuous current capacity (Engineered to withstand up to 900 A heavy overload operations lasting up to 8 hours).
Mating Interface Compatibility: Standardized European DIN 47636 and CENELEC EN 50180 / EN 50181 Interface C Sub-Surface Connection Profiles.
Core Application Layout: Explicitly engineered to deliver balanced, deadfront high-voltage terminal links inside medium-voltage gas-insulated switchgear (GIS) cabinets, outdoor pad-mounted step-up distribution transformers, and underground cable branching boxes. Supplied complete with a factory-tested tin-plated copper clamping double-headed bolt assembly.
Why Us?
- Reliable Supply Chain
- Quick Response
- Technical Support
- Genuine Product Authorization
Description
Product Specifications
Product Name/Series: Eaton Cooper Power Series Shielded Symmetrical T-Body Cable Connector (DT400/DT436 Series)
Maximum Rated System Voltage (Um): 24 kV Class (Perfectly optimized for standard 12/20 kV, 15 kV, and 15.2 kV distribution grids)
- Lightning Impulse Insulation Withstand: 125 kV Peak Crest Parameters.
- AC Power Frequency 5-Minute Withstand Voltage: 54 kV rms Symmetrical Baseline.
Continuous Base Current Capacity: Rated for 600 A / 630 A continuous current carrying loops with an 8-hour maximum overload capacity of 900 A.
Short Circuit Fault Current Withstand: Validated up to 35 kA Symmetrical Peak for 1 full second duration.
Cable Cross-Section Accommodations: Accommodates extruded polymeric cables (XLPE/EPR) ranging seamlessly from 35 mm² up to 400 mm².
Symmetrical Array & Voltage Configuration Matrix
The Eaton Cooper Power series symmetrical deadbreak T-connector infrastructure is tightly structured across dedicated catalog codes to handle distinct insulation outer diameters and core dimensions:
- Low-Range Conductor Layouts (35 mm² – 70 mm²): Utilizing specialized inner stress relief cones tailored for tight core clearances in utility branching circuits.
- Mid-Range Distribution Layouts (95 mm² – 240 mm²): Precision-calibrated to fit standard domestic and import single-phase or three-phase underground industrial networks.
- High-Stress的大截面 Layouts (300 mm² – 400 mm²): Utilizing rugged heavy-gauge bimetallic inertia-welded compression connectors built for wind array clusters and solar farm step-up loops.
Material & Structural Characteristics
- Direct-Molded Peroxide-Cured EPDM Rubber: Formulated, mixed, and molded entirely in-house to create a uniform, high-density insulation body that resists chemical oxidation and polymer tracking in severe environments.
- Semi-Conductive External EPDM Shielding Screen: Heavy-duty, molded outer skin that remains at absolute zero earth potential during live grid operation, ensuring 100% deadfront safe operator exposure.
- Pre-Molded Internal Geometric Stress Relief Cone: Advanced stress cone profile formulated to systematically smooth out high-voltage electrical field concentrations around the cable screen break.
- Tin-Plated High-Torque Double-Headed Clamping Screw: Heavy-gauge brass clamping hardware ensures low contact resistance and eliminates thermal drift under constant transformer vibration.
- Molded-In Screen Earthing Eyes: Features integrated, low-impedance grounding loop links pre-molded into the outer jacket to allow fast connection of copper earth drain lines.
- Dual Capacitive Test Points with EPDM Protective Caps: Equipped with an internal capacitive test point under a watertight grounding shield cap to allow safe circuit voltage status checking via standard line indicators.
Product Functions
1. Symmetric High-Voltage Potential Balancing: The symmetrical T-body design distributes physical installation stress evenly across switchgear bushings, minimizing mechanical bending moments in compact cabinets.
2. Deadfront Hermetic Submersion Shielding: Establishes a 100% fully screened, fully submersible, and dust-tight cable connection link that operates safely even under long-term direct water submersion.
3. Sectionalizing Grid Isolation Flexibility: Serves as a versatile disconnect terminal block; its rear-facing C-interface can be safely sealed with an epoxy insulating plug or expanded with rear coupling surge arresters.
Key Features
1. Zero Safe Phase Air Gap Requirement: Fully insulated deadfront geometry removes the need for standard phase-to-phase air separation clearances, dramatically down-scaling the total footprint of switchgear enclosures.
2. Tool-Free Quick Field Deployment: Requires no specialized hydraulic field-heating or chemical wrapping tapes; the entire component block is ready for full-load energization immediately after securing the tightening stud.
3. Non-Aging Bio-Fluid Chemical Compatibility: Formulated using premium polymers proven to maintain total structural stability and zero swelling when fully submersed in hot transformer mineral oil or plant-based Envirotemp FR3 fluids.
4. 100% Factory Partial Discharge Certification: Every production unit undergoes definitive automation quality tests including high-pC micro-volt screening, 100% partial discharge testing under 10 pC thresholds, and periodic X-ray integrity analysis.
FAQ
Q1:How about your after-sales service?
Q2:We only need some products inner parts/components, could you sell that?
Q3:How long is our delivery time?
Q4. what services can we provide?
Accepted Delivery Terms: FOB, CIF, EXW, DDU;
Accepted Payment Currency: USD;
Accepted Payment Type: T/T, L/C, D/P D/A, MoneyGram, Credit Card, PayPal, Western Union, Cash, Escrow;
Language Spoken: English, Chinese
Related products
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series 8.3kV 50kA-Interrupting ELSP Under-Oil Backup Current-Limiting Fuse for Pad-Mounted Transformer
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series Dual-Sensitive Bay-O-Net Fuse Link 4000358C05B / 4000358C10B for Dual-Fuse Transformer Protection
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series Four-Position Sectionalizing Loadbreak Switch (15kV-38kV, 200A-630A) for Loop-Feed Switchgear
- Pad-Mounted Transformer Accessories
Eaton Cooper Power Series 23kV 150kV-BIL Bay-O-Net Fuse Assembly 4000361C99FV / 4001177B51MC for Power Utility & Subsurface Substation